LP Direct Ex Heater

ELECTRICAL DIRECT HEATER – MODEL LP-(*)A, MODEL LP-0AHP or MODEL LP-(*)S

explosion proof heaters

IECEx

Categories: ,

Description

1 Application

Direct-heaters for Hazardous locations, designed for direct mounting onto e.g. manifolds etc.

  • Freeze protection
  • Anti-condensation
  • Temperature maintenance

2 Features and Advantages

  • Self-limiting heating elements
  • Small dimensions
  • No moving parts, no maintenance required, therefore long lifetime
  • Suitable for T4 and T3 classifications
  • Can be used for 110/240 VAC/DC

3 Remarks

  • All Cameo Heaters are designed around self-limiting heating elements. These self-limiting semi-conductor elements are saving power consumption. Our Cameo Direct-heaters are designed to heat the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
  • Optional body #5 : 4 holes diam. 5,2 mm. available in Aluminium  and SS range
    For easy mounting, at no extra charge
  • Alternative 316 Stainless Steel heaters can be delivered for the 100-10 Watt range.
    Also possible is an aluminium body with four holes drilled through (body #5), for easy mounting.
    Please see below for further technical data.

4 Range

LP-1AT3ca. 115 °C Surface temperature100-10 Watt
LP-2AT4ca. 105 °C Surface temperature100-10 Watt
LP-3AT4ca. 90 °C Surface temperature100-10 Watt
LP-4AT4ca. 70 °C Surface temperature100-10 Watt
LP-0AHP (High Power model)T3ca. 130 °C Surface temperature200-20 Watt

* these temperatures are measured at 20 °C ambient temperature.

5 Technical data

Power100-10 Watt or 200-20 Watt for High Power model
Electrical cable3 x 1 sqmm, braided std.
Material cablebraided silicone, optional: non-braided cable
Standard lengthca. 1 mtr. Other lengths optional
Overall dimensions78 x 30 x 34 mm (LxWxH)
WeightAluminium heater ca. 350 g., 316 Stainless Steel 360 g.
Materialblack anodized aluminium (A) or 316 stainless steel (S)
Protection classII 2G Ex d IIC T4 or T3

II 2D Ex tD A21 IP66 T 135°C or T200 °C
CertificationKEMA 01ATEX2124X and IECEx DEK 11.0017
IP degreeIP 66
Voltage110/240 VAC/DC
Ambient temp. range– 60 °C … + 90 °C
Optional body #54 holes diam. 5,2 mm. available in Aluminium range.
for easy mounting, at no extra charge.

Additional Technical data for the High Power model LP-0AHP, T3, 130 °C:
Overall dimensions88x36x36 mm (LxWxH)
Materialblack anodized aluminium only
All other datathe same as standard model

6 Datasheet