GLP Heater

ELECTICAL DIRECT HEATER – GENERAL PURPOSE MODEL GLP- *A

Description

1 Application

Space-heaters for Non-hazardous locations are designed for

  • Freeze protection
  • Anti-condensation
  • Temperature maintenance

2 Features and Advantages

  • Self-limiting heating elements
  • Small dimensions
  • No moving parts, no maintenance required, therefore long lifetime
  • Can be used for 110 / 240 VAC/DC

3 Remarks

  • All Cameo Space-heaters are designed around self-limiting heating elements. These semiconductor elements are saving power consumption.
  • Our Cameo Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
  • When required in other applications, e.g. analyzers, it is normal practice to use our Space-Heaters in combination with our Fix-Therm96 thermostats (range from 10 °C up to 135 °C).
  • Do not cover the fins to guarantee free convection.

4 Range

GLP-1A - T3ca. 115°C Surface temperature100-10 Watt
GLP-2A - T4ca. 105°C Surface temperature100-10 Watt
GLP-3A - T4ca. 90°C Surface temperature100-10 Watt
GLP-4A - T4ca. 70°C Surface temperature100-10 Watt
GLP-0AHP - T3
(High power model)
ca. 130°C Surface temperature200-20 Watt
* these temperatures are measured at 20°C ambient temperature.

5 Technical data

Power consumption100-10 Watt or 200-20 Watt
Electrical cable3 x 1 sqmm
Material cablenon-braided silicone cable
Standard lengthca. 1 mtr., other lengths optional
Other lengthsto be specified
WeightAluminium heater ca. 350 g., 316 Stainless Steel 480 g.
Overall dimensions78 x 30 x 34 mm (LxWxH)
Materialblack anodized aluminium (A) or 316 stainless steel (S)
Voltage AC/DC110/240

6 Datasheet

Download