Description
1 Application
Space-heaters for Non-Hazardous locations are designed for
- Anticondensation
- Freeze protection
- Temperature maintenance
2 Features and Advantages
- Self-limiting heating elements
- Small dimensions
- No moving parts, no maintenance required, therefore long lifetime
- Can be used for 110/240 VAC/DC
3 Remarks
- All SMART Space-heaters are designed around self-limiting heating elements. These semi-conductor elements are saving power consumption.
- Our SMART Space-heaters are designed to heat the air inside an enclosure and indirectly the installed equipment. If properly selected for freeze protection, no thermostat will be needed.
- When required in other applications, e.g. analyzers, it is normal practice to use our SMART Space-heaters in combination with our Fix-Therm96 thermostats (range from 10°C up to 130°C)
- Do not cover the fins to guarantee free convection!
4 Range
GSMLP-1A | ca. 115°C Surface temperature | 100-10 Watt |
GSMLP-2A | ca. 105°C Surface temperature | 100-10 Watt |
GSMLP-3A | ca. 90°C Surface temperature | 100-10 Watt |
GSMLP-4A | ca. 70°C Surface temperature | 100-10 Watt |
GSMLP-0AHP (High power model) | ca. 130°C Surface temperature | 200-20 Watt |
5 Technical data
Power consumption | 100-10 Watt or 200-20 Watt |
Electrical cable | 3 x 1 sqmm |
Material cable | non-braided silicone cable |
Standard length | ca. 1 mtr., other lengths optional |
Weight | ca. 1400 g. |
Other lengths | to be specified |
Overall dimensions | 100 x 54 x 54 mm (LxWxH) |
Material | black anodized aluminium |
Voltage AC/DC | 110/240 |